Dual 120mm Fan Duct for ASICs
The dual 120mm fan duct brings two matching miner fan positions into a common exhaust route. It is a passive printed shroud for selected Antminer and IceRiver chassis, useful when the hole pattern and outlet dimensions match the installation.
- Fan-side format: Dual 120mm positions
- Material: PLA printed plastic
- Function: Passive shroud / duct adapter
Entry configuration price. Confirm the selected size, controller and packing list before ordering.
$13.00
9999 em stock
Forma de pagamento
Dada a rápida evolução do mercado, os preços das máquinas de mineração podem sofrer flutuações; por favor, confirme o preço mais recente junto da nossa equipa de vendas antes de efetuar o pagamento, para evitar perdas financeiras.
Poupe nos custos de envio ao encomendar duas ou mais máquinas! Contacte hoje mesmo a nossa equipa de vendas para obter o melhor orçamento.
Descrição:
The dual 120mm fan duct brings two matching miner fan positions into a common exhaust route. It is a passive printed shroud for selected Antminer and IceRiver chassis, useful when the hole pattern and outlet dimensions match the installation.
Choose the adapter by measurements rather than by an assumed universal fit. The listed construction is PLA, so clearance from hot surfaces and suitable operating temperatures need particular attention. A plastic duct has no electronic temperature cutoff and cannot replace a blower controller.
Dual 120Mm Fan Duct: specifications and selection
| Fan-side format | Dual 120mm positions |
|---|---|
| Material | PLA printed plastic |
| Function | Passive shroud / duct adapter |
| Model examples | Selected S21, T21, S19, L7 and IceRiver KS units |
| Required checks | Hole pitch, fan frame spacing, outlet diameter and heat exposure |
Which miners and installations are suitable?
Selected Antminer AL1, S21, T21, S19j XP, S19k Pro and L7; IceRiver KS5M and KS5L after matching the actual mounting pattern. A complete cooling conversion may require a separate blower and fan-signal interface.
The Dual 120mm fan duct is an aftermarket accessory. Compatibility references identify selection candidates, not original-manufacturer endorsement or an unconditional fit guarantee. The quotation should identify the exact dimensions, supplied configuration and included accessories.

Installation and operating checks
Measure the connection on the actual machine before choosing a size. Inspect the mounting surface and allow access for future maintenance. Fit the component without blocking the miner intake, straining wiring or placing unsupported duct weight on the fan frame. Confirm the fastening method and packing contents before work begins.
For an exhaust installation, keep the duct route short and avoid sharp bends or crushed sections. Check the completed joints for leakage and vibration. A passive accessory does not increase fan pressure or remove the heat generated by the miner. Compare operating temperatures before and after installation at a stable load.
For wiring tasks, isolate the equipment first and use materials with the required documented ratings. Keep adhesive and plastic parts away from unsuitable hot surfaces. Do not cover ventilation openings or use an accessory to conceal a damaged connector. Restore normal protective functions before operating the machine.
Selection questions
Will the dual fan duct silence the miner by itself?
No. It directs airflow into a connected duct. Sound depends on fans, air speed, vibration and the room. Confirm that added duct resistance does not raise chip or power-supply temperatures.
What information helps PunkHash check an order?
Send the full miner model and revision, clear fan and PSU-label photos, the measured connection sizes, required quantity and destination voltage and frequency. For a cooling project, include the room temperature and planned exhaust route. These details make the recommendation more useful than a brand-only enquiry.
Related control boards and power supplies
For model-specific repair planning, review CV1835 Control Board for Antminer; Fonte de alimentação APW17 1215 para Antminer S21 e S19j XP; Placa de controlo IceRiver para KS1, KS2, KS3, KS3L, KS3M, KS5L e KS5M. These are separate products. Match the board revision, PSU label, output range and connectors before adding any replacement to an order; a cooling accessory does not establish electrical compatibility.
For Antminer operating limits and original instructions, consult BITMAIN Support. Follow the corresponding original manufacturer guidance for other brands.
To select the Dual 120mm fan duct, contact PunkHash with your installation details. Ask us to confirm the configuration, accessories, lead time and shipping quote before payment.
Sobre os transportes:Os mineradores em stock serão enviados no prazo de 3 dias úteis. No caso de encomendas em grande quantidade enviadas através da DHL Express, UPS, FedEx ou TNT, por favor, considere um prazo adicional de 1 a 2 dias para o processamento.
Os prazos de entrega dos mineradores encomendados antecipadamente dependem do calendário de produção da fábrica. As datas estimadas de envio são indicadas na página da encomenda; no entanto, os envios efetivos podem sofrer atrasos devido a questões relacionadas com a produção.
O nosso processo de envio funciona segundo o princípio “primeiro a pagar, primeiro a ser enviado”. Assim que o pagamento integral for recebido, faremos o possível para organizar o envio o mais rapidamente possível. Os pagamentos efetuados por transferência bancária (T/T) podem demorar entre 3 a 7 dias úteis a serem verificados, enquanto os pagamentos efetuados através de criptomoedas são normalmente confirmados no prazo de algumas horas a 1 dia útil.
O envio internacional demora normalmente entre 5 e 8 dias úteis; no caso de regiões remotas, os prazos de entrega podem prolongar-se para 8 a 10 dias úteis.
*Todas as transações constituem vendas definitivas e não são reembolsáveis após a sua conclusão. Agradecemos a sua compreensão, uma vez que esta é uma prática habitual no setor.
Avaliações
Limpar filtrosAinda não existem avaliações.