The Gen 2 ASIC blower silencer uses a brushless DC blower and a 150mm outlet to support a planned exhaust route for air-cooled mining equipment. Choose this generation when you need adjustable airflow and have measured the miner-side adapter, duct and installation space.
- Input: 220V; verify nameplate and local frequency
- Motor: Brushless DC, adjustable speed
- Outlet outer diameter: 150mm
Entry configuration price. Confirm the selected size, controller and packing list before ordering.
$65.00
9999 disponibles
Forma de pago
Dado que el mercado cambia rápidamente, los precios de la maquinaria minera pueden variar; por favor, confirma el precio más reciente con nuestro equipo de ventas antes de realizar el pago para evitar pérdidas económicas.
¡Ahorra en gastos de envío al pedir dos o más máquinas! Ponte en contacto con nuestro equipo de ventas hoy mismo para obtener el mejor presupuesto.
Descripción:
The Gen 2 ASIC blower silencer uses a brushless DC blower and a 150mm outlet to support a planned exhaust route for air-cooled mining equipment. Choose this generation when you need adjustable airflow and have measured the miner-side adapter, duct and installation space.
The motor is described as a 220V unit with stepless adjustment. Standard and WiFi configurations must be distinguished when ordering: remote control and protective functions depend on the actual controller supplied. A blower changes the airflow system; it does not make the miner heat load disappear.
Gen 2 Asic Blower Silencer: specifications and selection
| Input | 220V; verify nameplate and local frequency |
|---|---|
| Motor | Brushless DC, adjustable speed |
| Outlet outer diameter | 150mm |
| Listed maximum power | 162W |
| Listed airflow / speed | 1300 m³/h / 1800 rpm; reference values |
Which miners and installations are suitable?
Selected Antminer S21, T21, S19, L9 and Z15 Pro units; Whatsminer M60, M50 and M30; Avalon A15, A14 and A13; IceRiver KS-series machines. Each family requires its own verified adapter and airflow check.
The Gen 2 ASIC blower silencer is an aftermarket accessory. Compatibility references identify selection candidates, not original-manufacturer endorsement or an unconditional fit guarantee. The quotation should identify the exact dimensions, supplied configuration and included accessories.

Installation and operating checks
Measure the original fan frame, mounting holes, miner opening and intended duct diameter before selecting an adapter. Keep the inlet unobstructed and avoid recirculating hot exhaust. A short, supported exhaust route with gentle bends is easier to evaluate than a long compressed hose.
Record the original chip temperatures, fan readings and room temperature at a stable mining load. After installation, compare those readings at the same load and ambient conditions. Check the power-supply cooling path separately. Reduce load or stop the machine if temperatures or alarms move outside the manufacturer’s limits.
If a fan-signal simulator is needed, confirm its connector and firmware compatibility first. A simulator does not prove that air is moving. Retain thermal protection, verify the blower starts reliably, and test controller behavior after a power interruption. Electrical installation requires a correctly rated supply and qualified handling.
Selection questions
Will the Gen 2 blower make every ASIC equally quiet?
No. Fan pitch, duct vibration, power-supply fans and room acoustics all affect the result. Compare noise readings at the same distance and load, and retain adequate cooling before choosing a lower speed.
What information helps PunkHash check an order?
Send the full miner model and revision, clear fan and PSU-label photos, the measured connection sizes, required quantity and destination voltage and frequency. For a cooling project, include the room temperature and planned exhaust route. These details make the recommendation more useful than a brand-only enquiry.
Related control boards and power supplies
For model-specific repair planning, review CV1835 Control Board for Antminer; Fuente de alimentación APW17 1215 para Antminer S21 y S19j XP. These are separate products. Match the board revision, PSU label, output range and connectors before adding any replacement to an order; a cooling accessory does not establish electrical compatibility.
For Antminer operating limits and original instructions, consult BITMAIN Support. Follow the corresponding original manufacturer guidance for other brands.
To select the Gen 2 ASIC blower silencer, contact PunkHash with your installation details. Ask us to confirm the configuration, accessories, lead time and shipping quote before payment.
Información sobre el transporte:Los mineros disponibles en stock se enviarán en un plazo de 3 días laborables. Para pedidos al por mayor enviados a través de DHL Express, UPS, FedEx o TNT, hay que tener en cuenta que el proceso de tramitación puede tardar entre 1 y 2 días adicionales.
Los plazos de entrega de los mineros reservados dependen del calendario de producción de la fábrica. Las fechas estimadas de envío se indican en la página del pedido; sin embargo, los envíos reales pueden sufrir retrasos debido a problemas relacionados con la producción.
Nuestro proceso de envío funciona según el principio de “por orden de pago”. Una vez recibido el pago completo, nos esforzaremos por tramitar el envío lo antes posible. Los pagos realizados mediante transferencia bancaria (T/T) pueden tardar entre 3 y 7 días laborables en verificarse, mientras que los pagos realizados mediante criptomonedas suelen confirmarse en un plazo de unas horas a 1 día laborable.
Los envíos internacionales suelen tardar entre 5 y 8 días laborables; en el caso de las zonas más alejadas, los plazos de entrega pueden prolongarse hasta entre 8 y 10 días laborables.
*Todas las transacciones se consideran ventas definitivas y no son reembolsables una vez realizadas. Agradecemos su comprensión, ya que se trata de una práctica habitual en el sector.
Valoraciones
Borrar filtrosNo hay valoraciones aún.