Antminer HHB42701 1U 수력 비트코인 채굴기 – 49.75 TH/s, 단상 전원

Antminer HHB42701 is a 1U hydro-cooled SHA-256 Bitcoin miner with a specified hashrate of 49.75 TH/s and wall power consumption of 1366W at 35°C. Its compact rack format, APW8-3 single-phase power supply configuration and Ethernet connectivity make it an option for mining installations with suitable water-cooling infrastructure.

  • Hashrate: 49.75 TH/s
  • Algorithm: SHA-256
  • Wall Power: 1366W at 35°C
  • Specified Efficiency: 27.45 J/TH
  • Cooling: Hydro cooling
  • Power Supply Configuration: APW8-3, single-phase
  • Form Factor: 1U rack chassis

Contact PunkHash for pricing, package contents and deployment requirements.

원래 가격은 $99.00였습니다.현재 가격은 $79.00입니다.

결제 방법

1487a2a7-2d12-464b-a0aa-6a3c23b13eac - png에서 변환됨

시장이 급변하고 있는 상황을 고려할 때, 채굴기 가격은 변동될 수 있습니다. 금전적 손실을 방지하기 위해 결제 전에 당사 영업팀에 최신 가격을 확인해 주시기 바랍니다.

기계를 2대 이상 주문하시면 배송비를 절약하실 수 있습니다! 최적의 견적을 받아보시려면 지금 바로 영업팀에 문의해 주세요.

설명:

Antminer HHB42701 — 49.75 TH/s in a 1U Hydro-Cooled Format

Antminer HHB42701 combines 49.75 TH/s of SHA-256 mining performance with a slim 1U chassis, hydro cooling and a single-phase power supply configuration. With specified wall power consumption of 1366W at 35°C, it provides clear operating parameters for planning rack space, electrical capacity and cooling requirements.

This configuration is intended for Bitcoin mining installations with an appropriate external water-cooling system and wired network connection.

Compact 1U Design for Rack Deployment

The HHB42701 measures 360 × 422 × 43 mm. Its low-profile chassis supports organized equipment layouts where vertical rack space matters.

For multi-unit installations, allow space for power cables, water connections, network cables and maintenance access. Check rack mounting compatibility before installation.

Single-Phase Power Configuration

The specified APW8-3 power supply configuration uses single-phase AC input. This is relevant for sites planning mining deployments around single-phase electrical infrastructure.

Before installation, confirm the actual power supply’s input voltage, connector requirements and circuit capacity. Single-phase operation alone does not establish compatibility with every household socket.

Hydro Cooling with Defined Operating Requirements

The HHB42701 uses water cooling to transfer heat into an external cooling circuit. The supplied specifications list:

  • Recommended inlet water temperature: 35°C
  • Water flow rate: 2 L/min ±10%
  • Water pressure limit: ≤3.5 bar
  • Ambient operating temperature: 0–40°C

These values help buyers assess whether their cooling system can support the miner. For multiple units, size the shared cooling system according to total heat load and hydraulic requirements.

Clear Power Consumption for Site Planning

The specified wall power consumption is 1366W at 35°C, with a listed efficiency of 27.45 J/TH.

At a constant 1366W, one miner would consume approximately 32.78 kWh over 24 hours. This calculation excludes any external cooling equipment powered separately.

Estimated daily electricity cost can be calculated as:

32.78 × your electricity price per kWh

Actual consumption depends on operating conditions, configuration and supporting equipment.

Antminer HHB42701 Technical Specifications

Parameter 사양
Product Antminer HHB42701
Form factor 1U
Mining algorithm SHA-256
Hashrate 49.75 TH/s
Wall power consumption 1366W at 35°C
Specified energy efficiency 27.45 J/TH
Operating frequency 545 MHz
Cooling method Hydro cooling
Power supply configuration APW8-3, single-phase
PSU connection specification Busbar and screws
치수 360 × 422 × 43 mm
Weight including packaging 6.5 kg
Network connection RJ45 Ethernet, 10/100M
Recommended inlet water temperature 35°C
Water flow rate 2 L/min ±10%
Water pressure limit ≤3.5 bar
Ambient operating temperature 0–40°C
Recommended humidity 20–80%
Listed noise level 67 dBA

Specifications describe the listed configuration. Confirm the supplied unit, accessories and operating requirements before ordering.

Who Is This Miner Suitable For?

The Antminer HHB42701 is an option for buyers who need a compact SHA-256 miner and already have, or plan to install, suitable hydro-cooling infrastructure.

Potential applications include:

  • Rack-based Bitcoin mining installations.
  • Mining sites using single-phase electrical infrastructure.
  • Hydro-cooling test and integration projects.
  • Multi-unit deployments where rack space and cooling layout require careful planning.

With a listed noise level of 67 dBA and an external cooling requirement, installation should be planned for a suitable equipment area.

Frequently Asked Questions

What is the Antminer HHB42701?

The Antminer HHB42701 is a 1U hydro-cooled SHA-256 miner. The listed configuration provides 49.75 TH/s with wall power consumption of 1366W at 35°C.

Does the HHB42701 use single-phase power?

Yes. The supplied specification lists an APW8-3 single-phase power supply configuration. Confirm input voltage, wiring and circuit requirements for the actual unit before installation.

Does it need an external water-cooling system?

Yes. The miner requires a suitable external cooling circuit. The listed operating parameters include a recommended inlet water temperature of 35°C, a flow rate of 2 L/min ±10% and a water pressure limit of 3.5 bar.

How much electricity does it use per day?

At a constant wall power of 1366W, calculated consumption is approximately 32.78 kWh per day. Separately powered cooling equipment adds to total site consumption.

Can it be used for solo Bitcoin mining?

Solo mining depends on the installed firmware and compatibility with your chosen solo pool or node setup. Confirm this configuration before ordering. Solo mining rewards are probabilistic and are not guaranteed by the miner’s hashrate.

Is 6.5 kg the net weight?

No. The supplied specification lists 6.5 kg including packaging.

What is included in the order?

Contact PunkHash to confirm the miner configuration, power supply, cables, cooling accessories and packaging included in your quotation.

PunkHash Supply and Technical Support

PunkHash supplies mining hardware and provides technical consultation for product selection and deployment planning.

For separate custom Solo miner projects, PunkHash also offers OEM/ODM services covering product design, research and development, branding, manufacturing and technical support. Custom project scope and compatibility are assessed according to your requirements.

Request a Quote

Contact PunkHash for Antminer HHB42701 pricing, package details and technical enquiries. Please include your order quantity, destination and available power and cooling infrastructure.

WhatsApp으로 PunkHash에 문의하세요

교통편에 관하여:재고가 있는 채굴기는 영업일 기준 3일 이내에 발송됩니다. DHL Express, UPS, FedEx 또는 TNT를 통해 발송되는 대량 주문의 경우, 처리 기간으로 인해 1~2일이 추가로 소요될 수 있으니 이 점 양해 부탁드립니다.
사전 주문한 채굴기의 배송 시기는 공장의 생산 일정에 따라 달라집니다. 예상 배송일은 주문 페이지에 안내되어 있으나, 생산 관련 문제로 인해 실제 배송이 지연될 수 있습니다.
당사의 배송 절차는 “선결제, 선배송” 원칙에 따라 운영됩니다. 전액 결제가 완료되는 대로, 가능한 한 신속하게 배송을 처리해 드리겠습니다. 은행 송금(T/T)을 통한 결제의 경우 확인에 영업일 기준 3~7일이 소요될 수 있는 반면, 암호화폐를 통한 결제는 일반적으로 몇 시간에서 영업일 기준 1일 이내에 확인됩니다.
해외 배송은 일반적으로 영업일 기준 5~8일이 소요되며, 외진 지역의 경우 배송 기간이 영업일 기준 8~10일까지 늘어날 수 있습니다.
*모든 거래는 최종 판매로 간주되며, 일단 완료되면 환불이 불가능합니다. 이는 업계의 일반적인 관행임을 양해해 주시기 바랍니다.

0 리뷰
0
0
0
0
0

아직 상품평이 없습니다.

“Antminer HHB42701 1U Hydro Bitcoin Miner – 49.75 TH/s, Single-Phase Power”의 첫 상품평을 남겨 주세요

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다

리뷰에 사진을 추가하려면 로그인해야 합니다.

이 상품을 본 고객은 다음 상품도 함께 보았습니다

Antminer HHB42701 1U 수력 비트코인 채굴기 – 49.75 TH/s, 단상 전원

재고 있음

원래 가격은 $99.00였습니다.현재 가격은 $79.00입니다.

Bitaxe Gamma 602 – 1.8 TH/s 데스크톱 비트코인 채굴기, 25W

재고 있음

원래 가격은 $99.00였습니다.현재 가격은 $69.00입니다.

Bitaxe Gamma Hex 1300 – 6× BM1370 데스크톱 비트코인 채굴기

재고 있음

원래 가격은 $399.00였습니다.현재 가격은 $359.00입니다.

비트메인 Antminer S23 Hyd 3U 비트코인 채굴기 – 1160 TH/s, 9.5 J/TH

재고 있음

원래 가격은 $31,000.00였습니다.현재 가격은 $29,800.00입니다.

Antminer S23용 BM1374 순정 ASIC 칩 – 분해용 칩

재고 있음

원래 가격은 $109.00였습니다.현재 가격은 $99.00입니다.