Syscooling SC-400T Wasserkühlungspumpe – Einbau- und Kaufberatung

Syscooling SC-400T water cooling pump. A compact 12V DC circulation pump for a suitably sized liquid loop. Select it by required operating flow and system resistance rather than free-flow output alone. Entry option price; confirm size and scope.

$18.00

9999 vorrätig

Zahlungsart

1487a2a7-2d12-464b-a0aa-6a3c23b13eac – konvertiert aus PNG

Angesichts der sich rasch verändernden Marktlage können die Preise für Bergbaumaschinen Schwankungen unterliegen. Bitte erkundigen Sie sich vor der Zahlung bei unserem Vertriebsteam nach dem aktuellen Preis, um finanzielle Verluste zu vermeiden.

Sparen Sie Versandkosten, wenn Sie zwei oder mehr Maschinen bestellen! Kontaktieren Sie noch heute unser Vertriebsteam, um das beste Angebot zu erhalten.

Beschreibung:

Syscooling SC-400T water cooling pump: A compact 12V DC circulation pump for a suitably sized liquid loop. Select it by required operating flow and system resistance rather than free-flow output alone. PunkHash helps buyers define the part and installation scope before combining it with the rest of a mining cooling circuit.

Syscooling SC-400T water cooling pump: selection details

Current model SC-400T; the earlier SC-300T is discontinued
Supply 12V DC; listed operating current 0.4–0.6A
Maximum listed flow 360L/h under the source test conditions
Maximum listed head 1.9m; maximum head and maximum flow are not simultaneous
Power interface Small 3-pin connector; confirm pinout before installation
Listed operating range −10 to 55°C; coolant and installation limits must also be checked

This small pump is not automatically suitable for a high-pressure factory Hydro miner. Provide the cold plate pressure drop, tubing length and desired working flow before selecting it. Confirm the connector pinout and separate power supply; do not connect it to an unverified controller header.

Check the operating point

Obtain the pressure drop through the cold plates and fittings, then compare the required working flow with the pump curve. Maximum free-flow output and maximum shutoff head describe different endpoints. Check electrical polarity, connector function and coolant limits. The pump does not replace a radiator, filtration arrangement or leak monitoring system.

Related electronics and service parts

Vergleichen replacement control boards by controller revision and firmware. Check mining power supplies against the miner voltage, output and communication interface. These catalogs are matching resources; a cooling accessory does not establish electronic compatibility.

Buyer questions about the Syscooling SC-400T water cooling pump

What information is needed for a matched quote?

Send the exact miner model, board or part revision, clear connection photographs, quantity and delivery country. For a radiator or pump, include the intended loop arrangement and operating heat load. Confirm the selected configuration, supplied accessories and selling unit in the itemized quotation.

How should the installation location affect selection?

Share the summer ambient temperature and available electrical supply. Sites in the UAE or Texas should evaluate heat rejection at their hottest expected conditions. In colder locations, discuss freeze protection and start-up conditions with the system designer. Shipping cost and delivery time depend on destination and the confirmed order.

Request a matched Syscooling SC-400T water cooling pump quotation from PunkHash. We can review the proposed component combination before you place the order.

Syscooling SC-400T water cooling pump

Zum Thema Verkehr:Vorrätige Miner werden innerhalb von 3 Werktagen versandt. Bei Großbestellungen, die per DHL Express, UPS, FedEx oder TNT versandt werden, rechnen Sie bitte mit einer zusätzlichen Bearbeitungszeit von 1–2 Tagen.
Die Lieferzeiten für vorbestellte Miner hängen vom Produktionsplan des Herstellers ab. Die voraussichtlichen Versandtermine werden auf der Bestellseite angegeben; jedoch kann es aufgrund von produktionsbedingten Problemen zu Verzögerungen beim tatsächlichen Versand kommen.
Unser Versandverfahren erfolgt nach dem Prinzip “Wer zuerst bezahlt, wird zuerst beliefert”. Sobald die vollständige Zahlung eingegangen ist, bemühen wir uns, den Versand so schnell wie möglich zu veranlassen. Zahlungen per Banküberweisung (T/T) können 3–7 Werktage zur Überprüfung benötigen, während Zahlungen per Kryptowährung in der Regel innerhalb weniger Stunden bis zu einem Werktag bestätigt werden.
Der internationale Versand dauert in der Regel 5–8 Werktage; in abgelegenen Regionen kann sich die Lieferzeit auf 8–10 Werktage verlängern.
*Alle Transaktionen gelten als endgültige Verkäufe und sind nach Abschluss nicht mehr erstattungsfähig. Wir bitten um Ihr Verständnis, dass dies branchenüblich ist.

0 Bewertungen
0
0
0
0
0

Rezensionen

Filter löschen

Es gibt noch keine Rezensionen.

Schreibe die erste Rezension für „Syscooling SC-400T water cooling pump – Fit & Buying Guide“

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert

Sie müssen angemeldet sein, um Fotos zu Ihrer Bewertung hinzufügen zu können.