{"id":13317,"date":"2026-09-15T00:38:51","date_gmt":"2026-09-15T08:38:51","guid":{"rendered":"https:\/\/www.punkhash.com\/?post_type=product&#038;p=13317"},"modified":"2026-09-19T22:38:36","modified_gmt":"2026-09-20T06:38:36","slug":"bitmain-antspace-hw7-2mw-hydro-mining-container","status":"publish","type":"product","link":"https:\/\/www.punkhash.com\/ar\/product\/bitmain-antspace-hw7-2mw-hydro-mining-container\/","title":{"rendered":"BITMAIN ANTSPACE HW7 2MW Hydro Mining Container"},"content":{"rendered":"<h1>BITMAIN ANTSPACE HW7 2MW Hydro Mining Container<\/h1>\n<h2>Next-Generation Hydro Infrastructure for High-Density Bitcoin Mining<\/h2>\n<p>The BITMAIN ANTSPACE HW7 is a next-generation 2MW hydro-cooling mining container developed for large-scale, high-density Bitcoin mining operations.<\/p>\n<p>Its flexible internal layout supports up to 396 standard T-type hydro-cooled mining servers or up to 242 rack-mounted 2U hydro miners, including the Antminer S23e U2H.<\/p>\n<p>By combining modular power distribution, coolant circulation, dry-tower cooling and evaporative cooling assistance, the HW7 provides a standardized infrastructure platform for mining companies, hosting operators, energy developers and institutional mining projects.<\/p>\n<p>[Request Project Pricing] [Talk to an Infrastructure Advisor]<\/p>\n<hr \/>\n<h2>Two Miner Formats. One Scalable Platform.<\/h2>\n<p>Unlike conventional mining containers built around only one miner form factor, the ANTSPACE HW7 supports two high-density deployment configurations:<\/p>\n<ul>\n<li>Up to 396 standard T-type hydro miners<\/li>\n<li>Up to 242 rack-mounted 2U hydro miners<\/li>\n<\/ul>\n<p>This allows project owners to select equipment according to power density, hashrate targets, hardware availability and future fleet-upgrade plans.<\/p>\n<p>Final capacity depends on the exact miner model, individual power consumption, coolant requirements and the approved electrical configuration.<\/p>\n<hr \/>\n<h2>Key Features<\/h2>\n<ul>\n<li>2,000kW hydro-cooling capacity<\/li>\n<li>Up to 396 standard hydro miners<\/li>\n<li>Up to 242 rack-mounted 2U hydro miners<\/li>\n<li>Compatible with Antminer S23e U2H configurations<\/li>\n<li>Approximately 1.031 PUE under specified conditions<\/li>\n<li>Dry tower with evaporative cooling assistance<\/li>\n<li>Modular 40-foot container design<\/li>\n<li>380\u2013480V wide-voltage input<\/li>\n<li>50\/60Hz grid compatibility<\/li>\n<li>Designed for high-density SHA-256 mining<\/li>\n<li>Supports phased mining-farm expansion<\/li>\n<li>Suitable for international industrial deployment<\/li>\n<li>North American and CE certification options<\/li>\n<\/ul>\n<hr \/>\n<h2>Higher Mining Density<\/h2>\n<p>The ANTSPACE HW7 is designed to help mining operators deploy more hashrate within a standardized container footprint.<\/p>\n<p>With capacity for up to 396 conventional hydro miners or 242 high-density 2U units, the HW7 can support large-scale fleet deployment while simplifying power distribution, coolant circulation and equipment management.<\/p>\n<p>When configured with 242 Antminer S23e U2H 865TH\/s miners, the theoretical installed hashrate could exceed 209PH\/s before accounting for actual operating availability, miner tolerance and site-level limitations.<\/p>\n<p>Actual deployed hashrate must be calculated using the final miner configuration.<\/p>\n<hr \/>\n<h2>Designed for 2U Hydro Mining<\/h2>\n<p>The arrival of high-density miners such as the Antminer S23e U2H changes how mining infrastructure must be designed.<\/p>\n<p>A single S23e U2H provides 865TH\/s while drawing approximately 8,650W. Deploying hundreds of these machines requires careful coordination between:<\/p>\n<ul>\n<li>Rack density<\/li>\n<li>Power distribution<\/li>\n<li>Coolant flow<\/li>\n<li>Heat rejection<\/li>\n<li>Transformer capacity<\/li>\n<li>Network infrastructure<\/li>\n<li>Maintenance access<\/li>\n<li>Safety systems<\/li>\n<\/ul>\n<p>The ANTSPACE HW7 is designed to support this new generation of rack-mounted hydro miners while remaining compatible with standard T-type configurations.<\/p>\n<hr \/>\n<h2>Hybrid Dry and Evaporative Cooling<\/h2>\n<p>The HW7 uses a dry-cooling tower supported by an evaporative cooling pad.<\/p>\n<p>Under moderate conditions, the dry-cooling system rejects heat without depending entirely on continuous water consumption. During higher-temperature periods, evaporative assistance can improve heat rejection and system stability.<\/p>\n<p>This combined approach expands the range of climates in which the container can operate.<\/p>\n<p>Actual cooling capacity and water consumption will depend on:<\/p>\n<ul>\n<li>Ambient temperature<\/li>\n<li>Relative humidity<\/li>\n<li>Site altitude<\/li>\n<li>Coolant supply temperature<\/li>\n<li>Installed miner load<\/li>\n<li>Cooling-tower configuration<\/li>\n<li>Water quality<\/li>\n<li>Maintenance condition<\/li>\n<\/ul>\n<p>A site-specific thermal analysis is required before installation, especially in very hot or humid regions.<\/p>\n<hr \/>\n<h2>Energy-Efficient Supporting Infrastructure<\/h2>\n<p>BITMAIN specifies a PUE of approximately 1.031 under conditions including:<\/p>\n<ul>\n<li>25\u00b0C ambient temperature<\/li>\n<li>35\u00b0C coolant supply temperature<\/li>\n<\/ul>\n<p>A PUE of 1.031 means that the supporting infrastructure uses approximately 3.1% of the miners\u2019 IT load under the stated test conditions.<\/p>\n<p>Actual site PUE will vary depending on temperature, miner load, pump speed, cooling demand, transformer losses and other site equipment.<\/p>\n<p>PUE should therefore be treated as a reference under specified conditions, not a guaranteed annual site result.<\/p>\n<hr \/>\n<h2>Main Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>ANTSPACE HW7<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Manufacturer<\/td>\n<td>BITMAIN<\/td>\n<\/tr>\n<tr>\n<td>Product Model<\/td>\n<td>ANTSPACE HW7<\/td>\n<\/tr>\n<tr>\n<td>Solution Type<\/td>\n<td>Hydro-cooling mining container<\/td>\n<\/tr>\n<tr>\n<td>Container Format<\/td>\n<td>40-foot modular container<\/td>\n<\/tr>\n<tr>\n<td>Cooling Capacity<\/td>\n<td>2,000kW<\/td>\n<\/tr>\n<tr>\n<td>Standard Miner Capacity<\/td>\n<td>Up to 396 T-type hydro miners<\/td>\n<\/tr>\n<tr>\n<td>2U Miner Capacity<\/td>\n<td>Up to 242 rack-mounted 2U miners<\/td>\n<\/tr>\n<tr>\n<td>Example 2U Model<\/td>\n<td>Antminer S23e U2H<\/td>\n<\/tr>\n<tr>\n<td>Cooling System<\/td>\n<td>Dry tower with evaporative cooling assistance<\/td>\n<\/tr>\n<tr>\n<td>Reference PUE<\/td>\n<td>Approximately 1.031<\/td>\n<\/tr>\n<tr>\n<td>PUE Test Condition<\/td>\n<td>25\u00b0C ambient \/ 35\u00b0C supply liquid<\/td>\n<\/tr>\n<tr>\n<td>Input Voltage<\/td>\n<td>380\u2013480V<\/td>\n<\/tr>\n<tr>\n<td>Grid Frequency<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Primary Application<\/td>\n<td>Industrial SHA-256 mining<\/td>\n<\/tr>\n<tr>\n<td>Deployment Type<\/td>\n<td>Modular mining farm and hosting infrastructure<\/td>\n<\/tr>\n<tr>\n<td>Certification<\/td>\n<td>North American and CE options<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>All specifications must be confirmed against the final BITMAIN technical documentation and selected project configuration before purchase.<\/p>\n<hr \/>\n<h2>Suitable Applications<\/h2>\n<h3>Large-Scale Bitcoin Mining<\/h3>\n<p>Deploy a high concentration of SHA-256 hashrate within a standardized modular system.<\/p>\n<h3>2U Mining Server Projects<\/h3>\n<p>Build infrastructure around high-density miners such as the Antminer S23e U2H.<\/p>\n<h3>Mining Hosting Facilities<\/h3>\n<p>Provide standardized hydro-cooled capacity for institutional or third-party mining customers.<\/p>\n<h3>Existing Mining-Site Expansion<\/h3>\n<p>Add a 2MW hydro module to sites with sufficient transformer, grid and civil infrastructure.<\/p>\n<h3>Power Monetization Projects<\/h3>\n<p>Convert available industrial power into deployable computing capacity, subject to utility, grid and project requirements.<\/p>\n<h3>Phased Mining-Farm Development<\/h3>\n<p>Start with one container and add additional HW7 modules as power and capital become available.<\/p>\n<hr \/>\n<h2>Site Requirements<\/h2>\n<p>Before ordering the ANTSPACE HW7, customers should confirm:<\/p>\n<ul>\n<li>Available utility capacity<\/li>\n<li>Transformer capacity and voltage<\/li>\n<li>380\u2013480V three-phase electrical system<\/li>\n<li>Medium-voltage and low-voltage distribution<\/li>\n<li>Grounding and electrical protection<\/li>\n<li>Site foundation and load-bearing capacity<\/li>\n<li>Dry-cooling tower installation area<\/li>\n<li>Ambient temperature and humidity<\/li>\n<li>Water availability and water quality<\/li>\n<li>Coolant and piping configuration<\/li>\n<li>Stable network connectivity<\/li>\n<li>Crane and unloading access<\/li>\n<li>Local permits and certifications<\/li>\n<li>Installation and commissioning responsibilities<\/li>\n<li>Maintenance and spare-parts plan<\/li>\n<\/ul>\n<p>The ANTSPACE HW7 is a major mining-infrastructure component, but it should not be presented as a complete mining site.<\/p>\n<p>Transformers, medium-voltage equipment, cabling, foundations, network systems, civil construction, installation and commissioning may need to be supplied separately.<\/p>\n<hr \/>\n<h2>HW7 or HD5: Which One Should You Choose?<\/h2>\n<table>\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>ANTSPACE HW7<\/th>\n<th>ANTSPACE HD5<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cooling Capacity<\/td>\n<td>2,000kW<\/td>\n<td>Approximately 1,500kW<\/td>\n<\/tr>\n<tr>\n<td>Standard Miner Capacity<\/td>\n<td>Up to 396<\/td>\n<td>Up to 308<\/td>\n<\/tr>\n<tr>\n<td>2U Miner Support<\/td>\n<td>Up to 242 units<\/td>\n<td>Not the primary configuration<\/td>\n<\/tr>\n<tr>\n<td>Cooling Technology<\/td>\n<td>Dry tower plus evaporative assistance<\/td>\n<td>Dry-cooling tower<\/td>\n<\/tr>\n<tr>\n<td>Target Deployment<\/td>\n<td>Higher-density and next-generation fleets<\/td>\n<td>Standard hydro fleet deployment<\/td>\n<\/tr>\n<tr>\n<td>Best Fit<\/td>\n<td>S23e U2H and mixed-format projects<\/td>\n<td>S19\/S21\/S23 standard hydro miners<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose the HW7 when the project requires higher density, 2U miner compatibility or broader environmental adaptability.<\/p>\n<p>Choose the HD5 when the project is based mainly on standard hydro miners and approximately 1.5MW modules are more suitable for the site.<\/p>\n<hr \/>\n<h2>Professional Project Support from PunkHash<\/h2>\n<p>PunkHash can assist with more than ANTSPACE sourcing.<\/p>\n<p>Our team can support:<\/p>\n<ul>\n<li>ANTSPACE HW7 procurement<\/li>\n<li>Antminer S23e U2H and hydro-miner sourcing<\/li>\n<li>Container and miner capacity planning<\/li>\n<li>Transformer and power-equipment matching<\/li>\n<li>International logistics<\/li>\n<li>Site deployment coordination<\/li>\n<li>Cooling and electrical requirement review<\/li>\n<li>Mining ROI scenario analysis<\/li>\n<li>Installation-resource coordination<\/li>\n<li>After-sales support<\/li>\n<\/ul>\n<p>Share your site location, electricity price, available power, preferred miner model and deployment schedule. We will help you evaluate the complete project configuration.<\/p>\n<hr \/>\n<h2>Frequently Asked Questions<\/h2>\n<h3>How many miners can the ANTSPACE HW7 hold?<\/h3>\n<p>It supports up to 396 standard T-type hydro miners or up to 242 rack-mounted 2U hydro miners.<\/p>\n<h3>Does the HW7 support the Antminer S23e U2H?<\/h3>\n<p>Yes. BITMAIN specifically identifies the S23e U2H as a compatible 2U miner configuration.<\/p>\n<h3>Does the HW7 include the cooling tower?<\/h3>\n<p>The HW7 solution is designed to operate with a dry tower and evaporative cooling pad. The final quotation must clearly state which cooling equipment, pipes, cables and accessories are included.<\/p>\n<h3>Is the transformer included?<\/h3>\n<p>A transformer should not be assumed to be included unless specifically stated in the quotation.<\/p>\n<h3>What transformer capacity is required?<\/h3>\n<p>Transformer selection depends on the miner configuration, number of containers, maximum system load, redundancy plan and local electrical standards. A qualified electrical engineer should approve the final design.<\/p>\n<h3>Is the PUE always 1.031?<\/h3>\n<p>No. The stated PUE is measured under specified conditions. Actual annual PUE changes with climate, miner load and supporting infrastructure.<\/p>\n<h3>Can it operate in hot climates?<\/h3>\n<p>The combined dry and evaporative cooling design improves high-temperature adaptability, but every project requires a site-specific thermal assessment.<\/p>\n<h3>Can PunkHash supply the miners and container together?<\/h3>\n<p>Yes. PunkHash can prepare an integrated proposal covering the HW7, compatible miners, transformers, power equipment, logistics and deployment requirements.<\/p>\n<hr \/>\n<h2>Request an ANTSPACE HW7 Project Quote<\/h2>\n<p>For an accurate proposal, please provide:<\/p>\n<ul>\n<li>Project country and site location<\/li>\n<li>Available power capacity<\/li>\n<li>Site input voltage<\/li>\n<li>Electricity price<\/li>\n<li>Preferred miner model<\/li>\n<li>Standard or 2U miner configuration<\/li>\n<li>Number of HW7 containers<\/li>\n<li>Target deployment date<\/li>\n<li>Transformer availability<\/li>\n<li>Required logistics scope<\/li>\n<li>Installation and commissioning requirements<\/li>\n<\/ul>\n<p><strong>PunkHash \u2014 Compute the Future, Together.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Deploy up to 396 standard hydro miners or 242 2U ASIC miners with the BITMAIN ANTSPACE HW7 2MW hydro-cooling container. Get project pricing and deployment support from PunkHash.<\/p>","protected":false},"featured_media":13318,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[128,194],"product_cat":[98,125,195],"product_tag":[],"class_list":["post-13317","product","type-product","status-publish","has-post-thumbnail","product_brand-bitmain","product_brand-other","product_cat-accessories","product_cat-bitmain","product_cat-other","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product\/13317","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/comments?post=13317"}],"version-history":[{"count":1,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product\/13317\/revisions"}],"predecessor-version":[{"id":13319,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product\/13317\/revisions\/13319"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/media\/13318"}],"wp:attachment":[{"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/media?parent=13317"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product_brand?post=13317"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product_cat?post=13317"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.punkhash.com\/ar\/wp-json\/wp\/v2\/product_tag?post=13317"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}